Depth Ranges
|
|
- Units of 0-5; 0-10; 0-20, 0-40:0-200; 0-400; 0-800;0 - 2000; 0 - 5000 Units.
- Manual and Auto ranging modes.
|
Phasing
|
|
Phase and Auto Phasing at depth ranges of 400 units.
Phase from 0-400, 200-600, 400-800, etc. up to 4600-5000 Units. |
Units
|
|
Meters or Feet. |
Operating Modes
|
|
Single or Interleaved Dual Frequency |
Frequencies
|
|
12 kHz; 24 kHz; 33 kHz; 40 kHz; 100 kHz; 200 kHz |
Resolution
|
|
- 1 cm or .1ft <=99.9 units
- 10 cm or .5ft >99.9 units
|
Accuracy
|
|
Meets or exceeds all current IHO hydrographic
requirements for single beam echo sounders
0-40m – ±2.5cm, 40-200m – ±5.0cm,
>200m – ±10.0cm |
Audio Alarm
|
|
User controlled audio alarm for shallow water, deep
water and bottom lost conditions. |
Alarm Contact Closure
|
|
Relay contact, 120 VAC @ 0.5 Amps or 24 VDC @ 1.0 Amps
(maximum). |
Sounding Rate
|
|
Maximum 18Hz; depth range and operating mode
dependant. |
Transmit Power
|
|
2 kilowatt (maximum) both Channel 1 and Channel 2 |
Sound Velocity
|
|
1400-1600 meters/second or 4595-5250 feet/second, user
selectable in 1 unit increments. |
Depth from Measurement
|
|
Provides depth measurements in the following modes:
Depth Below Surface (DBS) or Depth Below Transducer (DBT). |
Data Output
|
|
- NMEA0183 Version 1.5, 2.0 and 2.1 strings:
- (9600 or 19200 baud, string dependent, No parity, 8 bits, 1 Stop bit) DBT, DBS
and DPT.
- ODEC proprietary serial strings-
- ODEC HEAVE, ODEC DEPTH, and ODEC BINARY for graph data output.
- Backwards compatible outputs-
- ODOM DBT, ODOM SBT, ATLAS DESO 25.
- Jumper selectable RS-232 or RS-422.
|
Data Input
COM 1
|
|
- NMEA0183 Version 1.5, 2.0 and 2.1 strings:
- (4800, 9600 or 19200 baud, string dependent, No parity, 8 bits, 1 Stop bit)
- GLL, GGA, RMC, RMA, VTG, ZDA.
- ODEC Proprietary Annotation String Input ANN.
- Jumper selectable RS-232 or RS-422.
|
Data Input
COM 2
|
|
- Heave Input :
- TSS, TSS1 or Seatex SOUNDER format, variable input rates,
- 9600, or 19200 depth output string dependent.
- Remote Annotation, Remote Fix Mark (ODEC Proprietary or ODOM compatible)
- External Synchronizatioin (sonar synch) and External Control.
|
Interference Rejection (IR) Filter
|
|
Removes ambient water column noise and/or simultaneous
transmissions from other acoustic systems within the frequency bandwidth of operation. |
Graphic Display
|
|
640 x 480 pixels; 16 grey shades,Cold Cathode
Flourescent Lighting ( CCFL) backlit flat panel display. |
Graphic Display Speed
|
|
Off to 20> cm/min on LCD Display. Off to >9
cm/min on TDU hardcopy output. |
Remote Display Output
|
|
- Transmits proprietary serial string (4800, 9600 or 19200 baud, No parity, 8 bits,
1 Stop bit), RS-422.
- Power supplied via Bathy-1500 Main Unit.
|
Internal Flash Storage
|
|
Stores at 1 second intervals, resolution of digitized
bottom depth and position, up to eight hours of operation. Stores at 1 second intervals,
up to 150 minutes of graph (acoustic return) data and position. |
External Mass (Disk) Storage
|
|
Optional adapter cable; Enables storage of all ASCII
text data for depth, position, speed, course, annotation and parameters and/or acoustic
graph information through paralell port interface to a SCSI compatible device. |
Printer Output
|
|
Centronics (paralell port) interface to TDU 850 Series
thermal grey scale recorders |
Input Power
|
|
115 / 230 VAC (switch selectable) 50 / 60 Hz; 60 Watts
Nominal (80 Watts with three remotes attached). |
Dimensions
|
|
39.4cm (15.5") width, 29.21 cm (11.5")
height; and 21.59 cm (8.5") deep |
Weight
|
|
10.7 kg (23.5 lbs.) |